Double Drum Hot Water Boiler

Short Description:

Double Drum Hot Water Boiler SZL Series assembled water tube boiler adopts longitudinal double drum chain grate boiler.


Product Detail

  • Capacity: 0.35MW~35MW
  • Type: Hot Water Boiler
  • Parameter :

    SZL Bearing Pressure Hot water Boiler

    Main Technology Parameter List

    Model

    Item

    SZL2.8-1.0/115/70-AII

    SZL2.8-1.25/130/70-AII

    SZL4.2-1.0/115/70-AII

    SZL4.2-1.25/130/70-AII

    SZL5.6-1.0/115/70-AII

    SZL5.6-1.25/130/70-AII

    Rated Capacity  2.8T/h4.2 T/h5.6 T/h
    Rated Working Pressure Mpa1.0/1.251.0/1.251.0/1.25
    Rated Steam Temp. 115/130115/130115/130
    Feed Water Temp. 707070
    Fuel Consumption  Kg/H~580~900~1130
    Thermal Efficiency  %788080
    Heating Surface Boiler Body m²80.5142178
    Economizer m²38.587.2122.08
    Grate area   m²4.847.7810.42
    Design FuleBituminous Coal
    Max. Transport Weight  30 T~25T~26T
    Max. Transport Dimension m6.9x2.5x3.5Up6.09x3.04x3.6

    D:7.3x2.86x1.72

    6.9x3.33x3.55
    Boiler Auxiliary Equipment Model and Specification
    Air BlowerModelT4-72-11 4A

    Right 315°

    T4-72-11 5A

    Right 225°

    GC8-1

    Right 225°

    Motor PowerN=5.5 KwN=11 KwN=11 Kw
    Draft FanModelY9-26 9D

    Right 0°

    Y8-39 9D

    Right 0°

    GY8-1

    Right 0°

    Motor PowerN=22 KwN=30 KwN=37 Kw
    Gear BoxModelGL-5PGL-10PGL-10P
    Motor PowerN=0.55 KwN=1.1KwN=1.1 Kw
    Feed Water PumpModel1½ GC5x72GC-5x52GC-5x4
    Motor PowerN=7.5 KwN=11 KwN=11 Kw
    Dust RemoverXD-4XD-6XD-8

    Model

    Item

    SZL7-1.0/115/70-AII

    SZL7-1.25/130/70-AII

    SZL10.5-1.0/115/70-AII

    SZL10.5-1.25/130/70-AII

    SZL14-1.0/115/70-AII

    SZL14-1.25/130/70-AII

    SZL17.5-1.0/115/70-AII

    SZL17.5-1.25/130/70-AII

    Rated Capacity  7T/h10.5 T/h14 T/h17.5T/h
    Rated Working Pressure Mpa1.0/1.251.0/1.251.0/1.251.0/1.25
    Rated Steam Temp. 115/130115/130115/130115/130
    Feed Water Temp. 70707070
    Fuel Consumption  Kg/H~1400~1900~2700~3650
    Thermal Efficiency  %82828282
    Heating Surface

    Radiation Tube39.4337.2158.458.4/68.4
    convection bank213.4284.68307.4307.4/384.8
    Economizer m²122.08130.8413413/521
    Grate area   m²11.9917.8122.5624.52
    Design FuleBituminous Coal (Low location of heat value:19228Ki/kg)
    Max. Transport Weight  ~40 T~43T~30T~30T
    Max. Transport Dimension 7.9x3.2x3.510x3.2x3.511x3.2x3.512x3.2x3.54

  • Previous: Double Drum Steam Boiler
  • Next: Coal Boiler Biomass Boiler I.D.Fan